PURPOSE
It is designed to control the crude oil flow surges under the conditions of the plug structure of the oil-andgas-
and-water mixture flow, as well as to separate the liberated petroleum gas.
UNITS SPECIFICATIONS
| Parameter | Value |
|
Maximum flow of oil-and-gas-and-water |
60 - 2000 |
|
Maximum volumetric fraction of the |
50; 90 |
| Operating pressure, MPa | 4,0 |
| Surge vessel wall temperature, °С | from minus 40 to plus 130 |
|
Pressure loss at maximum flow of |
0,05 |
PARAMETERS OF THE MEASURED MEDIUM
| Parameter | Value |
| Temperature, ° C | 0 - 70 |
| Kinematic viscosity range, m2/s | from 1·10-6 to 10·10-3 |
| Density, kg/m3 | 800 - 1360 |
| Hydrogen sulphide content in associated gas: | |
| - @ pressure to 1.7 MPa | 4 % of volume |
| - at pressures up to 4 MPa and partial pressure of hydrogen sulphide up to 345 Pa | 0.02 % of volume |
Megagroup.ru