PURPOSE
Measurement of the crude oil mass in the flow of oil-andgas-and-water mixture (at constant and variable volumes) without its prior separation.
METERS SPECIFICATIONS
| Parameter | Value |
| Flow range, t/day | from 1·10 to 420 |
| Maximum operating pressure, MPa | 4.0 |
|
Meter allowable basic relative error |
± 2.0 |
PARAMETERS OF THE MEASURED MEDIUM
| Parameter | Value | |
| Operating pressure (sch.), MPa (kgf/cm²) |
4,0 and 6,3 |
|
| Temperature, ° C |
common design | 0 - 70 |
| high-temperature design "B" | 0 to plus 120 | |
| corrosion-resistant design "K" | 0 to plus 100 | |
| Density, kg/m3 (default value, 820 kgf/cm3) | 500 - 1500 | |
| Kinematic viscosity upper value, m2/s | to 10·10⁻4 | |
|
Allowable content (volume fraction) of |
2 - 50 | |
|
Content of |
At pressure under |
4 |
|
At pressure over |
1 | |
Megagroup.ru