MEASURING UNIT TSYKLON

PURPOSE

Measurement of weight and volume of crude oil and liberated associated petroleum gas after the oil-andgas-
and-water mixture separation in the separatorsurge vessel, as well as determination of water proportion in the well product (with moisture meter or under samples analysis).

 

 

 

UNITS SPECIFICATIONS

Parameter Value
Maximum operating pressure, MPA 4,0
Flow range
- at crude oil volume measurement under the operation conditions, m³/day 2 - 210
- at crude oil weight measurement under the operation conditions, t/day from 2 ·10⁻3 to 420
- at liberated associated gas volume measurement under the operation conditions, m³/day 27 - 10290
Measurement allowable relative error within the flow range, %, not over
- crude oil weight ± 2,5
- crude oil volume under the operation conditions ± 0,75
- volume of crude oil reduced to standard conditions ± 1,0
- volume of liberated associated petroleum gas under the operation conditions ± 4,0
- volume of liberated associated petroleumgas reduced to standard conditions ± 5,0

PARAMETERS OF THE MEASURED MEDIUM

Parameter Value
Temperature, ° C 0 to plus 110
Density, kg/m3 700 - 1360
Kinematic viscosity range, m2/s from 1 to 1·10-2

Volumetric content (fraction) of liberated associated petroleum gas in
oil-and-gas-and-water mixture at flow and pressure value at the time of
measurement, %

0 - 98
Volume fraction of water in measured medium,% 0 - 98

Content of hydrogen sulphide in liberated
associated petroleum gas acc. to volume, %

@ 1.83 MPa 4
At pressure over 1.83 MPa to max operating pressure 1